IVC-160A

Auto Chemistry Analyzer

Innovative Design Leads
The Future

Simple and novel appearance design,
constant speed 150 T/H.

Efficient

Integration of professional design, constant speed 150 T/H, smoother & more efficient daily work

Reliable

Selection of key components and strict reliable design

Accurate

150μl minimum reaction volume, micro volume of 2ul sampling, 0.1ul sampling accuracy

Friendly

Easy to use operation interface, simple and fast operation mode

Every little detail leads to a new experience

Integration of professional design, daily work smoother, more efficient.

 

Intelligent Sampling

Intelligent frequency conversion sampling technology makes sampling more accurate, anti-collision protection can largely extend the service life of sampling probe.

Reagent Tray, Sample Tray

80 reagent positions, non-stop cooling system with peltier pad inside, 40 sample positions.

Accurate Temperature Control

Maintenance-free solid constant temperature fully enclosed direct heating, accurate temperature control, more accurate results.

Waterfall Flushing Position

The innovative 360 degree waterfall flushing position makes the cleaning of sampling probe, cleaning probe and mixer more efficient.

Advanced Operation System

User friendly software interface, easy to use.

System will mask test items or samples and alarm automatically when reagents, calibrators or samples are exhausted.

Whole process real-time monitoring.

Real-time monitoring of the whole reaction process and dynamic display of reaction curve, temperature, reagent remaining volume and other information.

IVC-160 Technical specifications

Test speed
Constant 150 tests/hour (Mono reagent or double reagent)
Sample tray
40 sample positions
Sample tube
Micro cup & Test tube & Blood collection tube can be used
Sample volume
2-30μL, step by 0.1μL
Reagent volume
20-300μl, step by 1μl
Reaction temperature
Peltier pad incubation system, reaction temperature (37℃ ± 0.1℃)
Mixer
paddle-type mixing, effective reducing of carry-over
Light source
Halogen lamp
Wavelength
340nm; 405nm; 450nm; 505nm; 546nm; 578nm; 630nm; 700nm(4 more options)
Power supply
AC 110/220V ± 10%, 50/60 Hz, 1000VA
Operation system
Windows XP, Windows 7, Windows 8, Windows 10
Water consumption
≤6L/hour(maximum)

Widely used in the field of in vitro diagnosis (IVD).

Widely used in the field of in vitro diagnosis (IVD). With supporting biochemical reagents, it can quickly detect more than 80 biochemical immune reagent items such as liver function, kidney function, myocardium, blood glucose, blood lipid and specific protein.